Test sequences Free Pro

Pass/fail limits, checked at capture

Every captured reading is checked against the limits of its step, and the result says why. Checking limits is free in every run, including the starter templates. Setting your own limits in a template is part of Pro, a one-time purchase; see Pricing.

iOS and Android, beta this winter.

Run screen in TestNMeasure: pin 7 shown as FAIL, above max 1 Ω
A failed pin, with the reason: above max 1 Ω.

Limit types

A step can use one of these limits Pro:

  • range: minimum ≤ value ≤ maximum
  • min: value ≥ minimum
  • max: value ≤ maximum
  • equals: the value equals the nominal at the reading's display precision
  • tolerance in percent: the nominal ± p %
  • tolerance absolute: the nominal ± a
  • expect open: passes on OL, or on a value at or above an optional threshold
  • none: no limits

You enter limits with a unit and prefix, for example ≤ 0.5 Ω or 11.4–12.6 V Pro. Bounds are inclusive, and values are compared exactly after conversion to SI, with no floating point.

Step editor in TestNMeasure: a measurement step with the range limit 11.4–12.6 V
One step with a range limit of 11.4–12.6 V.

OL and UL

OL passes a min limit and an expect-open limit, and fails all others. UL passes a max limit and fails all others Pro. A passing OL or UL keeps its reason on the result. With no limits, every reading, OL and UL included, is recorded as n/a with the reason no limits.

The reason is on the card

Each result stores a reason: in limits, below min, above max, out of tolerance, OL or UL accepted, unit mismatch, manual verdict, or no limits. The step card shows it, for example "FAIL · above max 0.5 Ω" Pro.

Wrong function or unit

A reading whose function or unit differs from the step's expectation evaluates to fail with the reason unit mismatch Pro. Units compare as strings: continuity is not Ω, and diode is not V. Only the prefix is normalised, so mV against V is not a mismatch. Before you capture, a banner says, for instance, "Meter on AC V — step expects DC V", once per step. Auto-capture is suspended while the meter is on the wrong function, and the button becomes Capture anyway, which records a fail with reason unit mismatch.

Fixed at capture

Limits are evaluated at capture, on redo and on amend. They are never re-evaluated when the template changes later, because a run keeps the template version it started on Pro. For the report built from a finished run, see PDF reports.

What it does and doesn't do (yet)

What it does
What it doesPlan
Set limits per step: range, min, max, equals, tolerance or expected open. Bounds are inclusive.Pro
Warns when the meter is on a different function than the step expects, and holds back auto-capture.Free

Pro is a one-time purchase and Cloud is a subscription, both in the app. See what is Free, Pro and Cloud.

Not yet, or not planned

  • Units compare strictly: continuity is not Ω, diode is not V.

Questions

Are limits inclusive?

Yes. A range of 11.4–12.6 V passes 11.4 V and 12.6 V, and a maximum of 0.5 Ω passes 0.5 Ω.

How is OL treated?

OL passes a min limit and an expect-open limit and fails every other limit. UL passes a max limit and fails every other limit. With no limits, OL and UL are recorded as n/a.

What if the meter is on the wrong function?

A banner warns you before you capture, and auto-capture waits. If you capture anyway, the step fails with the reason unit mismatch.

Coming to iPhone and Android.

iOS and Android, beta this winter.

Questions or a meter to suggest? Mail support@testnmeasure.app.