Guide · updated 24 November 2026
How to Use a Multimeter
To use a multimeter, plug the black probe into COM and the red probe into the jack for what you measure, turn the dial to the right function, and touch the probes to the circuit: across a part for voltage, across a part with the power off for resistance and continuity, and in series with the load for current. Read the value and its unit on the display. This guide explains the dial and the jacks, the safety rules, and each basic measurement step by step.
iPhone and iPad (iOS 17 or later): free on the App Store. Android later.

At a glance
| Measurement | Dial | Red probe | How the probes go |
|---|---|---|---|
| DC voltage | VΩ | Across the part, circuit on | |
| AC voltage | VΩ | Across, with a rated meter and probes | |
| Resistance | VΩ | Across, power off | |
| Continuity | VΩ | Across, power off | |
| Current | A or mA | In series, circuit opened | |
| Capacitance | VΩ | Across, discharged, power off | |
| Diode | VΩ | Red on the anode, power off |
The black probe always goes in COM.
Safety first
Safety. Use a meter and probes rated for the place you measure: the CAT rating (CAT II, III or IV) and the voltage printed next to it must cover the circuit. Check the probes before use: no cracked insulation, no bare metal above the finger guards, and keep your fingers behind the guards. Never measure current with the probes across a voltage source. Switch the power off for resistance, continuity, capacitance and diode tests. If you are not trained for mains work, do not measure mains circuits.
CAT II is for equipment plugged into an outlet, CAT III for the fixed installation of a building (distribution boards, fixed wiring), and CAT IV for the supply side (the meter and the service entrance). A higher category is built for larger voltage spikes. A meter rated CAT III 600 V is not safe on a CAT IV circuit, even at a lower voltage.
The dial, the jacks and the display
The dial picks the function. Each position has a symbol: V with a straight line for DC voltage, V with a wavy line for AC voltage, Ω for resistance, a sound-wave symbol for continuity, a diode symbol, A for current, and often capacitance, frequency and temperature. A function button (SELECT or FUNC) switches between functions that share a position. The multimeter symbols chart explains every marking.
The jacks take the probes. Black always goes in COM. Red goes in the V/Ω jack for voltage, resistance, continuity, diode and capacitance, in the mA or µA jack for small currents, and in the A (often 10 A) jack for large currents. Current jacks are protected by a fuse.
The display shows the value, its unit (mV or V, Ω, kΩ or MΩ) and symbols for the mode. OL means the value is over the range, or, on resistance and continuity, an open path. A meter with auto-range picks the range itself; on a manual meter, pick the first range above the value you expect, and step down if the reading is small.
Measure voltage
DC voltage
- Put black in COM and red in V/Ω.
- Turn the dial to DC volts (V with a straight line).
- Touch black to minus (or ground) and red to plus. The probes go across the part; the circuit stays as it is.
- Read the value. A minus sign means the probes are the other way round; nothing is damaged.
A battery is the easiest first measurement. See how to test a battery with a multimeter for the steps and the charts that tell you what the number means, and the car battery voltage chart for a 12 V battery.
AC voltage
AC voltage is measured the same way as DC, with the dial on V with a wavy line. Polarity does not matter. Mains voltage can kill: use a meter and probes rated for the circuit, keep one hand away from the circuit where you can, and connect the black probe first and remove it last. On a disconnected wire a sensitive meter can show a few volts of "ghost voltage" picked up from nearby cables; some meters have a low-impedance mode (LoZ) that ignores it.
Resistance and continuity
Measure resistance
- Switch the power off and, for a reliable value, take the part out of the circuit or lift one of its legs. Other parts in parallel change the reading.
- Put the probes in COM and V/Ω and turn the dial to Ω.
- Touch the probe tips together first. The small value you see is the resistance of the leads; subtract it from low readings, or use the REL button to zero it.
- Touch the probes to both ends of the part and read the value and the unit (Ω, kΩ or MΩ).
To check a resistor against its marking, read the bands with the resistor colour code chart and compare. Do not hold both probe tips and the part with your fingers: on high values, your body adds a parallel path.
Test continuity
Continuity tells you whether a path exists: the meter beeps when the resistance between the probes is below a threshold, often somewhere between 20 Ω and 50 Ω. Turn the dial to the continuity symbol, switch the circuit off, and touch the two ends of the wire, switch or fuse. A beep means connected; silence and OL mean open. The full procedure is in how to test continuity with a multimeter, and a fuse check in how to test a fuse with a multimeter.
Measure current
Current is the measurement that destroys meters and fuses, because the meter must be in series: the current flows through it.
- Switch the power off.
- Move the red probe to the current jack: the A jack if you do not know the size of the current, the mA jack only if you know it is small enough for that input's fuse.
- Turn the dial to A (DC or AC, as the circuit).
- Open the circuit at one point and connect the meter into the gap, so all of the current flows through it.
- Switch on and read the value. Switch off before you disconnect.
Never put the probes across a battery or a supply while the red probe is in a current jack: the meter is then almost a short circuit, and the fuse blows or worse. After a current measurement, move the red probe back to V/Ω. A clamp meter measures current around a single wire without opening the circuit. For a car battery that goes flat while parked, the parasitic draw test uses this series method.
Capacitance and the diode test
Capacitance. Switch off, discharge the capacitor through a resistor, take it out of the circuit if you can, and turn the dial to the capacitance symbol. Large capacitors take several seconds to read. Compare the value with the marking and its tolerance. The steps and what the readings mean are in how to test a capacitor with a multimeter.
Diode test. In the diode position the meter drives a small current through the part and shows the voltage across it. A good silicon diode reads about 0.5 to 0.7 V with red on the anode and OL the other way round. A reading near 0 V both ways means a short; OL both ways means open. An LED reads higher, and may glow faintly if the meter's test voltage is high enough.
Common mistakes
- The red probe left in the current jack after a current measurement, then a voltage measurement: a short through the meter.
- Measuring resistance with the power on. The reading is wrong, and the meter can be damaged.
- Reading the wrong unit. 4.7 kΩ and 4.7 MΩ look alike on a small display; check the unit every time.
- The wrong range on a manual meter: OL means the range is too low, a reading of 0.00 often means it is too high.
- A meter with a flat battery, which can show readings that drift or are simply wrong. Replace it when the low-battery symbol shows.
- A meter rated too low for the place you measure. Check the CAT rating before you work on an installation.
Log readings with a Bluetooth meter
With a Bluetooth multimeter, the TestNMeasure app shows the same reading on your phone. Tap the meter in the scan results to connect, and live readings start. The large readout shows which digits have settled, and an over-range shows as OL, never as a number. Swipe to a live graph of the readings. Hold freezes the reading in the app, and REL takes the lead resistance off resistance readings. One tap saves the current reading. A reading from a meter the app does not read can be typed in and is marked as manual. Export the session as CSV. Which meters the app reads is on the meters page; see also the live meter and quick capture. A test file is your record, not a certification.

Meters that can do this
Bluetooth multimeters from our shop that make this measurement and that TestNMeasure reads live.
- ZOYI ZT-5B in the TestNMeasure shop
- ZOYI ZT-5BQ in the TestNMeasure shop
- ZOYI ZT-300AB in the TestNMeasure shop
- ZOYI ZT-5566S in the TestNMeasure shop
Other meters the app reads live
What the app does here, and what it doesn't
| What it does | Plan |
|---|---|
| Tap a result to connect; the meter becomes the active instrument and live readings start. | Free |
| Type the reading from any instrument; typed values are marked as manual. | Free |
| A large readout that shows which digits have settled; OL and UL are shown as OL and UL, never as a number. | Free |
| Swipe the readout to a live graph with min and max lines, pan and zoom. | Free |
| Hold freezes the displayed reading and statistics in the app, independent of the meter's own HOLD. | Free |
| REL shows the difference from a stored reference, for example to null out test-lead resistance. | Free |
| One tap saves the current reading, with an Undo. | Free |
| Export log sessions and test files as CSV, free. | Free |
Not yet, or not planned
- A test file is your record, not a certification.
Questions
How do I use a multimeter for the first time?
Put black in COM and red in V/Ω, turn the dial to DC volts and measure a battery: black on minus, red on plus. Then try resistance on a resistor with the power off, and continuity on a wire. Leave current until you have read how the series connection works.
Which setting do I use to measure voltage?
V with a straight line (often with dashes) for DC, such as batteries, car circuits and electronics. V with a wavy line for AC, such as mains outlets. Use the first range above the voltage you expect if your meter is not auto-ranging.
Why does my multimeter show OL?
OL means overload or over-range: the value is above the selected range, or, on resistance and continuity, the path is open. Pick a higher range, or check that the probes touch clean metal and the path is complete.
Can I measure current like voltage, across the part?
No. Current is measured in series, with the circuit opened and the meter in the gap. With the probes across a voltage source in a current jack, the meter is a short circuit and the fuse blows.
Try it in the demo
A simulation of the app in your browser, with made-up readings: no meter and no install needed.
Get TestNMeasure for iPhone and iPad.
iPhone and iPad (iOS 17 or later): free on the App Store. Android later.
Questions or a meter to suggest? Mail support@testnmeasure.app.
No ad networks, no sign-up.